Views: 0 Author: Site Editor Publish Time: 2026-11-27 Origin: Site
SOLAS categorizes totally enclosed lifeboats into "cargo version" and "tanker type" (fire-protected) versions. The primary reason for this is that the risk environments encountered by different types of vessels in distress vary significantly. In its LSA (Life-Saving Appliances) Code, the IMO establishes distinct, mandatory protection requirements for these two scenarios, striking a balance between safety compliance and economic efficiency.
CARGO VERSION
For general dry-cargo vessels—such as bulk carriers and container ships—the cargo does not include flammable liquids. Consequently, the primary risks involve the vessel sinking, exposure to severe weather and heavy seas, or extreme cold; scenarios such as large-scale oil fires on the sea surface or the spread of toxic oil vapors are rare.
Therefore, the version of the lifeboat designed for these vessels requires only basic, fully enclosed, self-righting capabilities and a standard suite of equipment—sufficient for conventional ship abandonment and escape. This design offers a simple structure, low self-weight, and minimal maintenance costs.
TANKER VERSION
Crude oil tankers, product tankers, chemical tankers, and liquefied gas carriers often transport flammable liquid cargoes with a flash point of ≤60°C. In the event of a leak, these substances can rapidly form an extensive, burning oil slick on the sea surface, accompanied by intense thermal radiation and toxic vapors. If a standard lifeboat were to enter such a fire zone, its interior temperature would spike, occupants would inhale toxic fumes, and the engine would likely stall.
Consequently, the International Convention for the Safety of Life at Sea (SOLAS) mandates that such vessels be equipped with "tanker-type" fire-protected lifeboats. These craft are fitted with an integrated water-spray cooling system and an independent air-supply system, enabling them to navigate safely through a surrounding oil fire for at least 8 minutes. By providing a supply of clean air to the interior, these systems protect both the occupants and the engine, allowing for a safe evacuation from the burning sea surface.
Both types of craft share the same basic FRP hull construction—the hull material itself is not inherently fire-resistant—with the key difference being the inclusion of a specialized fire-protection system. This bifurcated design approach ensures compliance with the stringent mandatory escape-protection standards for liquid-cargo vessels, while sparing standard cargo vessels from the unnecessary burdens of procurement, annual inspection, and maintenance.