LYG series pressure water tank

This pressure water tank can be used to provide fresh water for living and cleaning of ship and drilling platforms.

Quantity:
  • LYG
  • EC&CCS
  • 0.4
  • 0.44
  • Marine pressure water tank
  • 40m Pressure Water Tank
  • 0.66
  • 15 days
  • ONBOARD Pressure Water Tank
  • 0-45 centigrade

1.Application
This pressure water tank is appropriate for the water supply system (fresh water, seawater) on board.

 

 

2.Principle Description

 

The device uses the pressure water pumped by water pump in tank to compress air so as to keep the water

 in tank under a proper pressure for the use on board.

 

 

Liquid level meter: To show the water level condition in tank.

 

Pressure gauge: To show the pressure in tank.

 

 

Pressure controller: To control the start and stop of water pump. When the pressure in tank is under 0.3Mpa,

 the water pump will start to feed water into tank until the pressure reaches 0.4Mpa.

 

 

Safety valve: When the pressure in tank is more than 0.42Mpa, the safety valve will open to release the pressure in tank.

 

Charge valve: To charge the compressed air into tank.

 

Discharging valve: To empty the water in tank when maintaining.

 

Control box: The control box is designed with two control modes, one is manual control, the other one is auto control. 

It is equipped with main water pump, spare water pump and change-over switch SA3. If select the main water pump, please turn the change-over switch SA3 to "Main", if select spare water pump, please turn SA3 to "Spare". When the change-over SA2 is turned to "manual", the main water pump or spare water pump will be start to work manually. 

When the change

over switch SA2 is turned to "auto", the device will enter into auto work. When the high pressure controller detects

 the pressure in tank has reached 0.4MPa, the main water pump or spare water pump will stop working.

 

 

3.Operation Manner

 

3.1 Gas-filled

 

3.1. 1 Start the compressor. Open the charge valve to change gas into tank until the needle of pressure gauge is

 directed to 0.1MPa. Then close charge valve, stop charging.
3.2 Adjust the range of control pressure

 

3.2. 1 Set the low pressure controller as 0.3Mpa, high pressure controller as 0.4MPa.
3.3 Adjust the take-off pressure of safety valve

 

3.3. 1 Adjust the take-off pressure of safety valve, when the pressure in tank is more than 0.42MPa, the safety valve will take off to 

release the pressure in tank.

 

3.4 Normal working

 

3.4.1 Open the water inlet and outlet valve

 

3.4.2 Turn the selective switch "main pump- spare pump" of control box to main water pump or spare water pump. Turn the change-over switch of water pump to "auto". When the pressure in tank is lower than 0.3MPa, the water pump will start 

automatically until the pressure reaches 0.4MPa.

 

4. Pipes 

4.1 Charge valve: Connected to the compressed air connector to fill in compressed air.
4.2 Water inlet and outlet: Connected to the outlet of water pump to inject water into tank.
4.3 The water outlet of safety valve: To discharge the pressure water. It is connected to bilge.

4.4 Discharging outlet: To empty all of the water in tank. It is connected to bilge.

 

Type A B C
Capacity(m3) 0.12 0.2 0.3 0.5 1 1.5 2 3
Working Pressure(Mpa)  0.6
Design Pressure(Mpa) 0.7
Strength Test Pressure(Mpa) 1.05
Tightness Test Pressure(Mpa) 0.87
Safety valve open Pressure(Mpa) 0.63

QQ图片20160705160040

Product Inquiry

Navigation

Contact Us

Address:  7F/8,Jintai Building,Nanping,Chongqing,400060,China 
Zip: 400060
Contact person:Nedved Jiang
Tel: 0086-023-62984891
Fax: 0086-023-62613622
Mobile: 0086 15922636020
E-mail: master@hy-industry.com
Skype: hangyumarine
Chongqing Gathering Marine Equipment Co., Ltd.    Powered by Leadong